Decorative round surface-mounted luminaire. For escape route illumination. Base: metal, powder-coated. Diffuser made of non-yellowing plastic (PMMA), opal. Diffuser fastening: patented push system. Suitable for Ceiling mounting, Wall (surface). Electronic ballast included. Self-contained system with automatic self-test. With integrated HF movement sensor. Functional parameters of the motion detector (ceiling mounting up to 4.0 m or wall mounting up to 2.7 m): HF detector 5.8 GHz ISM frequency band. Sensitivity/Range: 1-8 m in diameter, adjustable from 20-100%. Time control between 10 seconds and 30 minutes, adjustable. Coverage: 120°. Can be used as master luminaire up to 800 W (ohmic load), 500 W (fluorescent lamp, LED) / 400 A, 200 µs. Suitable for outdoor use to a limited extent only, as it is sensitive to all movements.
Technical Specifications
Typ of emergency lighting | Self-contained system |
---|---|
Monitoring | Autotest |
Battery | NiMh |
Duration | 8 h |
Operating mode | Non-maintained power mode and maintained power mode |
Diameter D | 460 mm |
Height H | 93 mm |
Weight | 2.6 kg |
Light source | LED |
Colour temperature | 3000 K |
Rated luminous flux, mains operation | 2050 lm |
System power, mains operation | 20 W |
Rated luminous flux, emergency operation | 80 lm |
System efficiency | 103 lm/W |
Glare evaluation RUG (4H 8H) | 19 |
Beam angle |
down 124° up 180° |
Rated life | 50000 h |
Colour rendering index (CRI) | 80 |
Colour tolerance (McAdam) | 4 SDCM |
Photobiological safety according to EN 62471 | Risk group 0 |
Driver | Converter |
Control | on/off |
Voltage | 230 V / 50 Hz, 60 Hz |
Luminaires on B10A fuse | 31 |
Luminaires on B16A fuse | 50 |
Luminaires on C10A fuse | 52 |
Luminaires on C16A fuse | 85 |
Inrush current / Inrush current duration | 5 A / 50 µs |
CIE Flux Code / CEN Flux Code | 42 72 91 85 100 |
Type of protection | IP 40 |
Protection class | I |
Filament test | 650°C - 30 seconds |
Impact resistance | IK03 |
Ambient temperature for maintained power | 5 °C ... + 30 °C |
Ambient temperature for non-maintained power mode | 5 °C ... + 40 °C |
Conformity mark | CE , EAC |