Robust protective tube luminaire for tough requirements. Rack made of sheet steel, white powder coated. End caps made of plastic (polyamide) grey. Diffuser made of plastic (polycarbonate), opal, shockproof. Symmetrical light distribution. Homogeneous light distribution. With accessories for wall, ceiling or pendant mounting. Suitable for through-wiring. With integrated HF movement sensor. Movement sensor functional parameters: Hold time: can be set with Casambi app. Range: up to 6 m, adjustable in 4 steps. Brightness sensor: adjustable in 5 steps. Factory setting: hold time adjustable via Casambi app, brightness threshold deactivated, detection range 100%. Mounting set must be ordered separately. Luminaires with limited surface temperature in accordance with DIN EN 60598-2-24 for use in environments in which a deposit of conductive dust on the luminaire can be expected. Qualified for use in the food and drink industry. Suitable for lighting in public car parks and public off-street parking spaces according to DIN 67528. Environmentally friendly and resource-saving due to replaceable components. Not a disposable luminaire.
Technical Specifications
Length L | 792 mm |
---|---|
Diameter D | 78 mm |
Weight | 1.66 kg |
Light source | LED |
Colour temperature | 4000 K |
Rated luminous flux | 3500 lm |
System power | 31 W |
System efficiency | 113 lm/W |
Glare evaluation UGR (4H 8H) | 25,3 |
Beam angle |
down 139°/106° up 180°/103° |
Rated life | 72000 h (L80/B50) |
Colour rendering index (CRI) | 83 |
Colour tolerance | 3 SDCM |
Photobiological safety according to EN 62471 | Risk group 1 |
Driver | Converter, dimmable |
Control | smart+free (Bluetooth) |
Voltage | 220 - 240 V / 0 Hz, 50 - 60 Hz |
Luminaires on B10A fuse | 22 |
Luminaires on B16A fuse | 37 |
Luminaires on C10A fuse | 38 |
Luminaires on C16A fuse | 62 |
Inrush current / Inrush current duration | 23 A / 176 µs |
CIE Flux Code / CEN Flux Code | 41 70 89 89 100 |
Type of protection | IP 67 |
Protection class | I |
Filament test | 750°C - 30 seconds |
Impact resistance | |
Ambient temperature | -20 °C ... + 30 °C |
Safety marks | D-mark , F-mark |
Conformity mark | CE , EAC |
Downloads
Light Calculator
The Online Light Calculator's purpose is a quick calculation and the results may not be perfectly accurate.