Central battery systems battery system (CPS) for mixed operation mode of all switching modes within one circuit. Simple scalability of the systems due to modular design. Choice of single-luminaire monitoring in mixed operation mode or circuit monitoring per end circuit. A location can be assigned for each luminaire, which is displayed in clear text in case of failure, to ensure clear localisation of the connected luminaires. Powerline communication is used for communication between the system and the luminaires. Bus lines to the luminaires are not necessary. Switching operations can be triggered via the series-standard digital inputs and messages can be forwarded to a superordinate GLT or a message and switchboard via the isolated changeover relay. Automatic generation of detailed system test log. 8 freely programmable inputs and 4 signalling alarms for central control technology (ready for operation, fault, battery operation and freely configurable), 1 bus output for external modules. Combination cabinet for electronics and batteries. Housing made of sheet steel, light grey (RAL 7035). Door hinge: right. Cable entry from above. 2 battery compartments, each (WxDxH) 750x550x270 mm. Up to 2 outlets for sub-distributors. The Compact Kombi II/E30 is prepared for installation in a separately available E30 fire protection housing. The housing is not included in the scope of delivery and must be ordered separately (E30 fire protection housing art. no. 985855). To comply with the allgemeine bauaufsichtliche Zulassung (national technical approval) Z-86.2-76, the separately available approved RZB E30 fire protection housing and the approved batteries must be used.
Technical Specifications
Monitoring | Luxifair AC-Control |
---|---|
Type of Installation | free-standing |
Charging current | 5 A |
Outgoing circuits | 48 |
Maximum connection power per final circuit | 580 W |
Luminaires per final circuit | 20 |
Luminaire monitoring | Single luminaire monitoring , Circuit monitoring |
Mixed operation | Yes |
Number of circuit modules | 12 |
Potential operating modes | Non-maintained , Maintained , Switched maintained , Staircase light switching |
Switching power | 9200 W |
Max. Switching power | 9200 VA |
Nominated voltage of battery | 216 V |
Output voltage mains | AC 230 V |
Output voltage emergency local | AC 230 V |
Output voltage emergency global | DC 216 V |
Input voltage | AC 230/400 V |
Terminal blocks (infeed) | 35 mm² |
Terminal blocks max. (output circuits) | 2.5 mm² |
Switch entrance | |
Network monitoring function | |
Potential remote station | |
Typ of emergency lighting | Central battery system |
Construction of system | Modular |
Touchscreen | |
Length L | 600 mm |
Width B | 800 mm |
Height H | 1800 mm |
Weight | 190 kg |
Voltage | 400 V / 50 Hz |
Type of protection | IP 20 |
Protection class | I |