Recessed LED downlight featuring advanced technology and sophisticated design. Housing: die-cast aluminium constructed as heat sink. Square cover plate: die-cast aluminium, powder coated. Round ceiling cut-out also with square types. Closed version. Cover clear single-pane toughened glass. Standard Gore™ Protective Vents diaphragm valve to avoid condensation. Luminaire also maintains the high protection type inside the false ceiling (does not apply to converter, IP 20). Faceted reflector: parabolic four-segment design, frosted aluminium, with highly polished light mixing chamber. MultiLumen: Luminous flux adjustable in different steps. Best colour rendering index Ra>90. Installation without tools thanks to spring fastening system. Connected converter included in separate gearbox. With connecting cable (L 250 mm). Suitable for through wiring as standard. Ball impact proof in accordance with DIN 18032-3. Qualified for use in the food and drink industry.

Technical Specifications

Length L 220 mm
Width B 220 mm
Height H 3 mm
Cut-out diameter DA 210 mm
Recess height HE 111 mm
Luminaire: recess height HEL 111 mm
Ceiling thickness S 1-20 mm
Weight 1.94 kg
Light source LED
Colour temperature 3000 K
Rated luminous flux 1600 lm, 2550 lm, 3450 lm, 4800 lm
System power 12 W, 19 W, 27 W, 41 W
System efficiency 117 lm/W | 128 lm/W | 133 lm/W | 134 lm/W
Glare evaluation UGR (4H 8H) 19,6 | 21,3 | 22,3 | 23,5
Beam angle 91°
Rated life 50000 h (L90/B50)
Colour rendering index (CRI) 92
Colour tolerance 2 SDCM
Photobiological safety according to EN 62471 Risk group 1
Driver Converter, dimmable
Control DALI
Voltage 220 - 240 V / 50 Hz, 60 Hz
Luminaires on B10A fuse 18
Luminaires on B16A fuse 30
Luminaires on C10A fuse 23
Luminaires on C16A fuse 36
Inrush current / Inrush current duration 50 A / 10 µs
CIE Flux Code / CEN Flux Code 79 100 100 100 100
Type of protection IP 65 on room side
IP 20
Protection class II
Filament test 850 °C
Impact resistance IK07
Ambient temperature -25 °C ... + 35 °C
Safety marks Ball impact proof in accordance with DIN 18032-03 , Do not cover the recessed luminaire!
Test marks ENEC , VDE
Conformity mark CE

Light Calculator

Room
Reflection rate 70 / 50 / 20
Calculation
Maintenance factor 0,8
Result
lx Illumination value Em
Quantity of Luminaires
lx Illumination value Em
W Total power
lm Total luminous flux
Download PDF

The Online Light Calculator's purpose is a quick calculation and the results may not be perfectly accurate.

Accessories

982703.002
Through-wiring box
982623.002