Recessed LED downlight featuring advanced technology and sophisticated design. Housing: die-cast aluminium constructed as heat sink. Square cover plate: die-cast aluminium, powder coated. Round ceiling cut-out also with square types. Closed version. Cover clear single-pane toughened glass. Standard Gore™ Protective Vents diaphragm valve to avoid condensation. Luminaire also maintains the high protection type inside the false ceiling (does not apply to converter, IP 20). Faceted reflector: parabolic four-segment design, frosted aluminium, with highly polished light mixing chamber. Installation without tools thanks to spring fastening system. Connected converter included in separate gearbox. With connecting cable (L 250 mm). Suitable for through-wiring. The converter is compatible with DC, making it ideal for central battery systems. Ball impact proof in accordance with DIN 18032-3. Qualified for use in the food and drink industry.
Technical Specifications
Length L | 130 mm |
---|---|
Width B | 130 mm |
Height H | 3 mm |
Cut-out diameter DA | 120 mm |
Recess height HE | 85 mm |
Luminaire: recess height HEL | 82 mm |
Ceiling thickness S | 1-20 mm |
Weight | 0.87 kg |
Light source | LED |
Colour temperature | 3000 K |
Rated luminous flux | 1900 lm |
System power | 18 W |
System efficiency | 106 lm/W |
Glare evaluation UGR (4H 8H) | 20 |
Beam angle | 49° |
Rated life | 50000 h (L90/B10) |
Colour rendering index (CRI) | 85 |
Colour tolerance | 3 SDCM |
Photobiological safety according to EN 62471 | Risk group 1 |
Driver | Converter |
Control | on/off |
Voltage | 220 - 240 V / 50 Hz, 60 Hz |
Luminaires on B10A fuse | 14 |
Luminaires on B16A fuse | 23 |
Luminaires on C10A fuse | 28 |
Luminaires on C16A fuse | 46 |
Inrush current / Inrush current duration | 16 A / 219 µs |
CIE Flux Code / CEN Flux Code | 94 99 100 100 100 |
Type of protection |
IP 65 on room side IP 20 |
Protection class | II |
Filament test | 850 °C |
Impact resistance | IK07 |
Ambient temperature | -25 °C ... + 35 °C |
Safety marks | Ball impact proof in accordance with DIN 18032-03 |
Test marks | ENEC , VDE |
Conformity mark | CE , EAC |
Downloads
Light Calculator
The Online Light Calculator's purpose is a quick calculation and the results may not be perfectly accurate.