Recessed LED projector for illuminating points to be highlighted. Housing: extruded aluminium profile, powder-coated. Projector has a horizontal rotation range of 340° and a vertical swivel range of 80°. Lockable projector orientation. Optical assembly with lens made of plastic (polycarbonate) for the best homogeneous light distribution - can be changed without tools. Installation without tools thanks to spring fastening system. Including separate LED converter with connecting cable 250 mm. For connection to the emergency power supply.
Technical Specifications
Typ of emergency lighting | Central battery system |
---|---|
Monitoring | Power circuit |
Battery | without |
Operating mode | maintained power mode |
Diameter D | 168 mm |
Height H | 177 mm |
Cut-out diameter DA | 160 mm |
Recess height HE | 125 mm |
Luminaire: recess height HEL | 51-63 mm |
Ceiling thickness S | 1-25 mm |
Weight | 1.77 kg |
Light source | LED |
Colour temperature | 4000 K |
Rated luminous flux, mains operation | 1100 lm |
System power, mains operation | 10 W |
Rated luminous flux, emergency operation | 1100 lm |
System power, emergency operation | 10 W |
System efficiency | 110 lm/W |
Glare evaluation UGR (4H 8H) | 14,2 |
Beam angle | 18° |
Colour rendering index (CRI) | 92 |
Colour tolerance | 2 SDCM |
Photobiological safety according to EN 62471 | Risk group 1 |
Driver | Converter |
Control | on/off |
Voltage | 220 - 240 V / 0 Hz, 50 Hz, 60 Hz |
Luminaires on B10A fuse | 31 |
Luminaires on B16A fuse | 50 |
Luminaires on C10A fuse | 52 |
Luminaires on C16A fuse | 85 |
Inrush current / Inrush current duration | 5 A / 50 µs |
CIE Flux Code / CEN Flux Code | 96 98 100 100 100 |
Type of protection | IP 20 |
Protection class | I |
Filament test | 650°C - 30 seconds |
Impact resistance | IK06 |
Ambient temperature for maintained power | -20 °C ... + 40 °C |
Ambient temperature for non-maintained power mode | -20 °C ... + 45 °C |
Conformity mark | CE |
Downloads
Light Calculator
The Online Light Calculator's purpose is a quick calculation and the results may not be perfectly accurate.